Tomzn Tovpd160ec Manual Better

Real-time digital display of voltage and current levels. 2. Technical Parameters (Better Setup Context)

Most errors occur here. Look at the top of the unit:

: Press and hold the DOWN arrow key for more than 12 seconds. The display will flash, restoring all values back to factory defaults. tomzn tovpd160ec manual better

To enter the setting mode, . Use the UP and DOWN keys to adjust values, then hold SET for 3 seconds again to save and exit. Default Value Adjustable Range A1 Power-on delay (reconnect time) 1s – 500s A2 Over-voltage protection value 230V – 300V (or OFF) A3 Over-voltage recovery value 225V – 295V A4 Recovery delay time (after over-voltage) 1s – 500s A5 Over-voltage protection action time 0.1s – 30s A6 Under-voltage protection value 140V – 210V (or OFF) A7 Under-voltage recovery value 145V – 215V A8 Recovery delay time (after under-voltage) 1s – 500s A9 Under-voltage protection action time 0.1s – 30s A10 Over-current protection value 1A – 63A A11 Recovery delay time (after over-current) 1s – 500s A12 Over-current protection action time 0.1s – 30s A13 Voltage calibration -9.5V to +9.5V A14 Over-current limit cycles (auto-lock) 1 – 20 times Operational Shortcuts & Indicators

: Use the UP and DOWN arrows to navigate and change parameters. Real-time digital display of voltage and current levels

Press and hold the DOWN button for more than 12 seconds to restore all default settings. Installation and Safety Tomzn Voltage Protector

Automatic cutoff during over-voltage (230V–300V) or under-voltage (140V–210V) events. Look at the top of the unit: :

Set the undervoltage threshold just below your normal minimum voltage—enough to detect a brownout or sag without nuisance tripping.